Climate Talk Fault Code Transmitted message Dealer error message Possible causes Corrective actions Unit Type Alarm Status Consumer error message
00 EEV OPEN CKT Not used yet     Thermostat    
01   Not used yet     Thermostat    
02   Thermostat internal communication error ClimateTalk coprocessor was not anle to start. •Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
•Replace thermostat if needed
Thermostat Critical  Internal hardware error
03   Thermostat internal communication error ClimateTalk coprocessor did not respond to commands. •Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
•Replace thermostat if needed
Thermostat Critical  Communication error
04   Thermostat software upgrade error  ClimateTalk firmware was not able to upgrade. •Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
•Replace thermostat if needed
Thermostat Critical  Communication error
05   Thermostat internal communication error ClimateTalk communication errors. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat minor  Communication error
06   Piezo speaker hardware error Piezo driver could not start due to hardware error. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat minor  Internal hardware error
07   LED hardware error LED driver could not start due to hardware issue. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat minor  Internal hardware error
08   Thermostat software upgrade error  OTA download signature is wrong, reverting back to previous firmware. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat minor  Communication error
09   Thermostat software upgrade error  OTA upgrade failed. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat minor  Communication error
0A   Proximity sensor hardware error Proximity sensor driver could not start due to hardware issue. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat minor  Internal hardware error
0B   Temperature/Humidity sensor hardware error Temp/Hum sensor driver could not start due to hardware issue. •Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option1)
•Replace thermostat if needed
Thermostat Critical  Internal hardware error
0C   Temperature/Humidity sensor hardware error Temperature sensor failed during operation. •Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
•Replace thermostat if needed
Thermostat Critical  Internal hardware error
0D   Temperature/Humidity sensor hardware error Humidity sensor failed during operation. •Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option 1)
•Replace thermostat if needed
Thermostat Critical  Internal hardware error
0E   Wi-Fi hardware error WIFI driver could not start due to hardware issue. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option1)
Thermostat minor  Internal hardware error
0F   Wi-Fi hardware error WIFI driver communication issue. •Check for proper 24 VAC powering thermostat.
•Conduct a warm start of the thermostat.
•Call Daikin support at 1-855-DAIKIN1(option1)
Thermostat minor  Communication error
1E   Heat Pump communication loss •data1 and data2 could be reversed
•loss of power to the unit.
•Loose, cut, or broken wire.
•Check polarity of Data1 and Data2.
•Check for any blown fuses or tripped breakers.
•Check for loose terminations, shorted or broken wires.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat Critical  Communication error
1F   Air Conditioner communication loss •data1 and data2 could be reversed
•loss of power to the unit.
•Loose, cut, shorted, or broken wire.
•Check polarity of Data1 and Data2.
•Check for any blown fuses or tripped breakers.
•Check for loose terminations, shorted or broken wires.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat Critical  Communication error
10   Thermostat reboot •Loss of power to system.
•Thermostat software update(OTA).
•Manual reboot of thermostat.
•No action needed. Thermostat minor  Communication error
20   EEV Coil communication loss •data1 and data2 could be reversed
•loss of power to the unit.
•Loose, cut, or broken wire.
•Check polarity of Data1 and Data2.
•Check for any blown fuses or tripped breakers.
•Check for loose terminations, shorted or broken wires.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat Critical  Communication error
21   Air Handler communication loss •data1 and data2 could be reversed
•loss of power to the unit.
•Loose, cut, or broken wire.
•Check polarity of Data1 and Data2.
•Check for any blown fuses or tripped breakers.
•Check for loose terminations, shorted or broken wires.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat Critical  Communication error
22   Furnace communication loss •data1 and data2 could be reversed
•loss of power to the unit.
•Loose, cut, or broken wire.
•Check polarity of Data1 and Data2.
•Check for any blown fuses or tripped breakers.
•Check for loose terminations, shorted or broken wires.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat Critical  Communication error
51   No ClimateTalk equipment discovered on network •data1 and data2 could be reversed
•loss of power to the unit.
•Loose, cut, or broken wire.
•Check polarity of Data1 and Data2.
•Check for any blown fuses or tripped breakers.
•Check for loose terminations, shorted or broken wires.
•Call Daikin support at 1-855-DAIKIN1(option 1)
Thermostat Critical  Communication error